Cleanroom Air Shower Room & Personnel Air Shower Systems
Biogreen air shower rooms create a controlled transition between gowning or uncontrolled areas and cleanroom spaces.
High-velocity filtered air is directed across personnel garments to remove loose particles, while interlocked doors help maintain cleanroom pressure and reduce cross-contamination.
Standard FLS series and custom air shower systems are available for pharmaceutical, electronics, semiconductor, medical device, food and other clean manufacturing environments.
High-Velocity Airflow
≥25 m/s Nozzle Velocity
High-Efficiency Filtration
≥99.99% @ ≥0.3 μm
Adjustable Cycle Time
0–99 s Adjustable
Interlocked Doors
Controlled Entry Sequence
≥99.99%
Filtration Efficiency @ ≥0.3 μm
≥25 m/s
Nozzle Air Velocity
0–99 s
Adjustable Shower Time
AC380V
3N, 50Hz Standard Supply
304 Stainless Steel
Cabinet / Interior / Doors
6–24
Nozzles by Model
PRODUCT OVERVIEW
A cleanroom air shower room is installed between a non-clean area and a clean area. It uses high-velocity clean air to blow off dust and particles carried by personnel, effectively reducing the amount of contaminants brought into the clean area.
Standard hinged-door air shower and automatic sliding-door air shower are both available in Biogreen FLS series.
- Double-side, single-side and three-side blowing configurations
- Manual swing door, automatic swing door, sliding door and automatic sliding door
- A / B / C / D straight-through door orientations and L-shaped entry/exit layouts
- High-quality 304 stainless steel or painted steel exterior with 304 stainless steel interior
HOW THE AIR SHOWER WORKS

Step 1
Enter the Chamber
The entry door closes and the interlock system confirms that the air shower cycle can begin.

Step 2
Filtered Air Is Accelerated
The blower draws return air through filters and accelerates clean air before it is delivered to the nozzles.

Step 3
High-Velocity Air Jets
Clean, high-velocity air is blown from multiple nozzles to remove loose particles from clothing and surfaces.

Step 4
Air Is Recaptured
Contaminated air returns to the lower sections, passes through filtration and is recirculated for the next cycle.
STANDARD FLS MODELS
Different facilities require different personnel throughput and installation space. Choose the right FLS model for your cleanroom entry.
Technical specification
FLS-1A
FLS-1C
FLS-2
FLS-X
Type
Single-person single-blow air shower
Single-person double-blow air shower
Double-person double-blow air shower
Multi-person double-blow air shower
Filtration efficiency
≥99.99% (@ ≥0.3 μm)
≥99.99% (@ ≥0.3 μm)
≥99.99% (@ ≥0.3 μm)
≥99.99% (@ ≥0.3 μm)
Nozzle air velocity
≥25 m/s
≥25 m/s
≥25 m/s
≥25 m/s
Air shower time
0–99 s adjustable
0–99 s adjustable
0–99 s adjustable
0–99 s adjustable
Nozzle quantity
6
12
18
24
Power supply
AC380V, 3N, 50Hz
AC380V, 3N, 50Hz
AC380V, 3N, 50Hz
AC380V, 3N, 50Hz
Rated power
0.55 kW × 1
0.55 kW × 2
0.65 kW × 2
0.75 kW × 2
Cabinet
High-quality 304 stainless steel, or painted steel exterior + 304 stainless steel interior
High-quality 304 stainless steel, or painted steel exterior + 304 stainless steel interior
High-quality 304 stainless steel, or painted steel exterior + 304 stainless steel interior
High-quality 304 stainless steel, or painted steel exterior + 304 stainless steel interior
Door
High-quality 304 stainless steel
High-quality 304 stainless steel
High-quality 304 stainless steel
High-quality 304 stainless steel
External size (W×D×H)
1200 × 1000 × 2100 mm
1400 × 1000 × 2100 mm
1400 × 1500 × 2100 mm
1400 × 2000 × 2100 mm
Working area (W×D×H)
800 × 900 × 1950 mm
800 × 900 × 1950 mm
800 × 1400 × 1950 mm
800 × 1900 × 1950 mm
Applicable persons
1 person
1 person
1–2 persons
1–3 persons
Real product display




APPLICATIONS

Pharmaceutical Manufacturing

Electronics & Semiconductor

Medical Device Manufacturing

Food & Cosmetic Processing

Laboratories & Biotechnology
REQUEST YOUR AIR SHOWER SOLUTION
Tell us your cleanroom class, personnel traffic, available dimensions and material requirements. Biogreen will recommend the right air shower model and configuration for your project.