CLASS II BIOLOGICAL SAFETY CABINET
Class II Biosafety Cabinet for Laboratory Biological Protection
Designed for controlled biological handling, this Class II biosafety cabinet combines front inflow, vertical downflow, high-efficiency filtration and a stainless steel work zone in one integrated BSC platform. The cabinet is available in 1000 mm and 1300 mm working widths with recirculating or total-exhaust airflow configurations.
The biological safety cabinet series is intended for laboratory workflows where personnel protection, product protection and control of cross-contamination are evaluated together with room layout and exhaust conditions.
ISO 5 Work Zone
1000 / 1300 mm Work Widths
Recirculating & Total-Exhaust Options
304 Stainless Steel Work Surface
Send your application, available cabinet width and laboratory exhaust conditions for model review.
ISO 5
Work-Zone Cleanliness
≥99.995% @ 0.12 μm
HEPA Filtration Value
0.33 ± 0.025 m/s
Downflow Velocity
0.33 ± 0.025 m/s
Inflow Velocity
≤65 dB
Operating Noise
≥900 LX
Illumination
A Controlled Work Zone for Biological Laboratory Procedures
A biological safety cabinet is a ventilated laboratory enclosure used to manage airborne contamination during procedures involving biological materials. In this BSC series, inward airflow at the front opening works together with vertically filtered downflow inside the chamber to create a controlled operating zone.
Depending on the selected configuration, filtered cabinet air is either partly recirculated inside the cabinet or discharged as total exhaust. The 1000 mm and 1300 mm sizes allow the bio safety cabinet to be matched to available laboratory space and operator requirements.
The cabinet structure combines a coated cold-rolled steel body, a 304 stainless steel work surface, negative-pressure containment around the work area, a movable front sash and dedicated lighting/UV-lamp provisions shown in the product specification.
- Microbiology
- Biotechnology
- Pharmaceutical Laboratory
- Medical / Clinical Laboratory
- Research Facilities

Choose the Right Biosafety Cabinet Configuration

1300 mm / Total Exhaust
- 100% total exhaust
- 1300 × 520 × 640 mm work zone
- 1465 × 760 × 2200 mm external size
- 1–2 persons
- 280 kg

1300 mm / Recirculating
- 30% exhaust / 70% internal recirculation
- 1300 × 520 × 640 mm work zone
- 1465 × 760 × 2200 mm external size
- 1–2 persons
- 270 kg

1000 mm / Total Exhaust
- 100% total exhaust
- 1000 × 520 × 640 mm work zone
- 1165 × 760 × 2200 mm external size
- 1 person
- 240 kg

1000 mm / Recirculating
- 30% exhaust / 70% internal recirculation
- 1000 × 520 × 640 mm work zone
- 1165 × 760 × 2200 mm external size
- 1 person
- 230 kg
Biosafety Cabinet Model Comparison
Compare the four configurations listed in the source product sheet by airflow mode, work-zone size, overall dimensions, lighting, weight and recommended operator count.
Parameter
BSC-1300 II B2
BSC-1300 II A2
BSC-1000 II B2
BSC-1000 II A2
Airflow Mode
100% total exhaust
30% exhaust / 70% internal recirculation
100% total exhaust
30% exhaust / 70% internal recirculation
Cleanliness Class
ISO 5
ISO 5
ISO 5
ISO 5
Filter Grade / Efficiency
HEPA: ≥99.995%, 0.12 μm
HEPA: ≥99.995%, 0.12 μm
HEPA: ≥99.995%, 0.12 μm
HEPA: ≥99.995%, 0.12 μm
Downflow Velocity
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
Inflow Velocity
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
0.33 ± 0.025 m/s
Noise
≤65 dB
≤65 dB
≤65 dB
≤65 dB
Vibration Peak
≤5 μm
≤5 μm
≤5 μm
≤5 μm
Power Supply
AC 220 V, 50 Hz
AC 220 V, 50 Hz
AC 220 V, 50 Hz
AC 220 V, 50 Hz
Personnel Protection
Impact sampler CFU ≤10; slit sampler CFU ≤5
Impact sampler CFU ≤10; slit sampler CFU ≤5
Impact sampler CFU ≤10; slit sampler CFU ≤5
Impact sampler CFU ≤10; slit sampler CFU ≤5
Product Protection
All sampling dishes CFU ≤5
All sampling dishes CFU ≤5
All sampling dishes CFU ≤5
All sampling dishes CFU ≤5
Cross-Contamination Protection
All sampling dishes CFU ≤2
All sampling dishes CFU ≤2
All sampling dishes CFU ≤2
All sampling dishes CFU ≤2
Work Zone (W×D×H)
1300 × 520 × 640 mm
1300 × 520 × 640 mm
1000 × 520 × 640 mm
1000 × 520 × 640 mm
External Size (W×D×H)
1465 × 760 × 2200 mm
1465 × 760 × 2200 mm
1165 × 760 × 2200 mm
1165 × 760 × 2200 mm
Front Sash Standard Opening
200 mm
200 mm
200 mm
200 mm
Front Sash Adjustable Position
160 mm
160 mm
160 mm
160 mm
Daylight / UV Lamp
30 W × 2 / 18 W × 1
30 W × 2 / 18 W × 1
20 W × 2 / 18 W × 1
20 W × 2 / 18 W × 1
Illumination
≥900 LX
≥900 LX
≥900 LX
≥900 LX
Weight
280 kg
270 kg
240 kg
230 kg
Recommended Operators
1–2 persons
1–2 persons
1 person
1 person
Construction
Coated cold-rolled steel body + 304 stainless steel work surface
Coated cold-rolled steel body + 304 stainless steel work surface
Coated cold-rolled steel body + 304 stainless steel work surface
Coated cold-rolled steel body + 304 stainless steel work surface
Model names and technical values above reproduce the supplied source sheet. Confirm the final 1000 mm recirculating model designation with the technical team before order placement or publication.
Three-Layer Protection Built Around the Work Zone
Personnel Protection
Source sampling-performance limits for biological safety personnel protection.
- Impact sampler: CFU ≤10
Product Protection
Source sampling-performance limit for product protection inside the work zone.
- All sampling dishes: CFU ≤5
Cross-Contamination Protection
Source sampling-performance limit for cross-contamination protection.
- All sampling dishes: CFU ≤2
Class II A2 & B2 Airflow Options
Recirculating Airflow Configuration

70% Internal Recirculation
30% Exhaust
Approximately 70% of filtered airflow is recirculated for continued use inside the cabinet, while approximately 30% is discharged after filtration. This layout reduces the amount of cabinet air sent to the exhaust path compared with a total-exhaust configuration.
Total-Exhaust Airflow Configuration

100% Exhaust
External Exhaust Coordination Required
The source product range also includes a 100% exhaust configuration. Cabinet airflow is filtered and directed to the exhaust path rather than being returned to the internal work-zone circulation, so project exhaust conditions should be reviewed during equipment selection.
Select the airflow configuration according to the laboratory process, handled materials, room exhaust conditions and applicable safety requirements.
Technical Specifications
Airflow & Performance
Parameter
Specification
Cleanliness Class
ISO 5
HEPA Filtration Value
≥99.995% at 0.12 μm
Downflow Velocity
0.33 ± 0.025 m/s
Inflow Velocity
0.33 ± 0.025 m/s
Noise
≤65 dB
Vibration Peak
≤5 μm
Protection Performance
Parameter
Specification
Personnel Protection
Impact sampler CFU ≤10; slit sampler CFU ≤5
Product Protection
All sampling dishes CFU ≤5
Cross-Contamination Protection
All sampling dishes CFU ≤2
Work Zone & Structure
Parameter
Specification
Available Work-Zone Widths
1000 mm / 1300 mm
Work-Zone Depth
520 mm
Work-Zone Height
640 mm
Front Sash Standard Opening
200 mm
Front Sash Adjustable Position
160 mm
Work Surface
304 stainless steel
Cabinet Body
Electrostatic baked-paint cold-rolled steel
Electrical & Lighting
Parameter
Specification
Power Supply
AC 220 V, 50 Hz
1300 mm Daylight / UV Lamp
30 W × 2 / 18 W × 1
1000 mm Daylight / UV Lamp
20 W × 2 / 18 W × 1
Illumination
≥900 LX
Applications

Microbiology Laboratories
For controlled handling of cultures, samples and microbiological procedures where airborne contamination needs to be managed within a defined work zone.

Biotechnology Research
Supports laboratory sample preparation and biological research workflows that require controlled airflow and a cleanable working chamber.

Pharmaceutical Laboratories
Can be considered for selected pharmaceutical R&D, microbiology and quality-control procedures after process and facility requirements are reviewed.

Medical & Clinical Laboratories
Provides a contained work zone for appropriate clinical and laboratory procedures involving biological samples, subject to the facility’s safety assessment and SOPs.

Cell & Tissue Research
The vertical filtered airflow and stainless work area support sensitive laboratory operations where both sample protection and operator-side containment are important.

Research Institutions
Suitable for universities, testing centers and R&D laboratories that require a Class II biological safety cabinet configuration matched to space and exhaust conditions.
FAQ
Need a Biosafety Cabinet for Your Laboratory Project?
Share the required work-zone width, airflow preference, application, quantity, destination and laboratory exhaust conditions. We can review the source-listed biosafety cabinet configuration and prepare the technical information needed for quotation.