H13/H14 HEPA Filter Cassettes for Cleanrooms

H13 / H14 | 200-2500 m³/h | Mini-Pleat / Separator / Gel Seal | Custom & Replacement Sizes

Biogreen HEPA filter cassettes are designed for high-efficiency final filtration in cleanrooms, FFUs, terminal filter housings and purification equipment. The product range includes H13 mini-pleat and separator HEPA filters as well as H14 gel-seal HEPA filters with standard catalog sizes and rated airflow options.

Select a HEPA air filter by filter grade, required airflow, initial resistance, frame depth and the sealing interface of the existing housing. For replacement projects, Biogreen can match the filter around the verified W × H × D dimensions and installation configuration.

Choose the HEPA Filter Construction for Your System

Mini-Pleat H13 HEPA Filter — JN-MPHF

A compact HEPA filter cassette using glass-fiber media, hot-melt pleat spacing and an aluminum-profile frame. The verified catalog range includes 50 mm, 70 mm and 90 mm depths with rated airflow from 200 to 2500 m³/h. This family is suited to applications where a relatively shallow final filter is required.

Separator H13 HEPA Filter — JNAF-YGK

A deeper separator-style HEPA filter with a hot-dip galvanized frame, glass-fiber media and the separator material stated in the catalog. Standard catalog depths are 150 mm and 220 mm, with rated airflow from 500 to 2500 m³/h. The deeper construction provides a different airflow and dust-loading profile from the mini-pleat cassette.

Gel-Seal H14 HEPA Filter — JN-GSHP / JN-SGSHP

The gel-seal HEPA filter uses a compact aluminum-profile construction and a liquid-channel sealing interface. The uploaded catalog shows side-channel and top-channel installation concepts, with H14 model series at 90 mm and 95 mm depths. This family is intended for terminal clean-air supply and high-cleanliness equipment interfaces.

What Does HEPA Filter Mean in a Cleanroom Specification?

HEPA means High Efficiency Particulate Air. In cleanroom procurement, however, the phrase alone is not enough to select a filter. The purchase specification should identify the required filter grade together with dimensions, rated airflow, initial resistance, frame construction and the sealing interface.

The uploaded Biogreen catalog identifies H13 mini-pleat and separator series and H14 gel-seal series. The catalog lists H13 efficiency at ≥99.99% and H14 gel-seal efficiency at ≥99.999%. The applicable test method should be confirmed in the project submittal rather than inferred from the consumer phrase “true HEPA filter.”

H13 Catalog Families

JN-MPHF mini-pleat and JNAF-YGK separator filters. Use when the project specification calls for the verified H13 catalog configuration.

H14 Catalog Family

JN-GSHP and JN-SGSHP gel-seal filters. Use where the project requires the H14 gel-seal catalog configuration and compatible housing interface.

HEPA Filter Cassette Construction

HEPA filter performance depends on more than the media. The frame must remain dimensionally stable, the media pack must be supported consistently, and the perimeter interface must prevent unintended bypass around the filter.

01 — Aluminum Profile Frame

Used on the verified mini-pleat and gel-seal product families to provide a light, stable cassette structure.

02 — Glass-Fiber Filter Media

The verified H13 and H14 HEPA families in the uploaded catalog use glass-fiber filter paper.

03 — Hot-Melt Pleat Separation

Mini-pleat and gel-seal families use hot-melt adhesive to maintain the pleat arrangement.

04 — Polyurethane Sealant

The media pack is sealed into the frame using the polyurethane sealing material stated in the catalog.

05 — Protective Face Mesh

Mini-pleat and gel-seal products use a baked-painted steel mesh face guard according to the catalog.

06 — Gel Channel or EVA Gasket

Gel-seal filters use a liquid-channel interface; the mini-pleat and separator families list EVA sealing strips in the catalog.

H13 Mini-Pleat HEPA Filter Models — JN-MPHF

The JN-MPHF mini-pleat H13 HEPA filter series covers shallow 50 mm, 70 mm and 90 mm catalog depths. Select the model by required face size, rated airflow and the listed initial resistance condition rather than by outside dimensions alone.

Verified materials: aluminum-profile frame, polyurethane sealant, hot-melt pleat separation, glass-fiber filter paper, baked-painted steel face mesh and EVA sealing strip. Maximum catalog operating conditions: 80°C and 80% RH.

Material

Aluminum profile

Sealant

Polyurethane

Separator

Hot-melt

Media

Glass-fiber

Face Guard

Steel mesh

Limits

80°C · 80% RH

Model Series

W × H × D (mm)

Rated Airflow (m³/h)

Initial Resistance

Filter Grade

Catalog Efficiency

JN-MPHF

320 × 320 × 50

200

120 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

484 × 484 × 50

400

120 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

630 × 630 × 50

700

120 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

320 × 320 × 70

300

120 Pa @ 0.6 m/s

H13

≥99.99%

JN-MPHF

484 × 484 × 70

600

120 Pa @ 0.6 m/s

H13

≥99.99%

JN-MPHF

630 × 630 × 70

900

120 Pa @ 0.6 m/s

H13

≥99.99%

JN-MPHF

570 × 570 × 70

500

105 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

1170 × 570 × 70

1000

105 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

1170 × 1170 × 70

2000

105 Pa @ 0.45 m/s

H13

≥99.99%

JN-MPHF

320 × 320 × 90

500

180 Pa @ 0.8 m/s

H13

≥99.99%

JN-MPHF

484 × 484 × 90

1000

180 Pa @ 0.8 m/s

H13

≥99.99%

JN-MPHF

630 × 630 × 90

1500

180 Pa @ 0.8 m/s

H13

≥99.99%

JN-MPHF

945 × 630 × 90

2000

180 Pa @ 0.8 m/s

H13

≥99.99%

JN-MPHF

1260 × 630 × 90

2500

180 Pa @ 0.8 m/s

H13

≥99.99%

class 10 clean room

H13 Separator HEPA Filter Models — JNAF-YGK

The JNAF-YGK separator HEPA filter uses a deeper frame than the mini-pleat family. The uploaded catalog lists 150 mm and 220 mm depths, H13 grade, ≥99.99% catalog efficiency and rated airflow from 500 to 2500 m³/h.

Verified materials include a hot-dip galvanized sheet frame, polyurethane sealant, the separator material stated in the source catalog as double-sided offset paper, glass-fiber filter paper and an EVA sealing strip. Maximum catalog operating conditions are 80°C and 80% RH.

Model Series

W × H × D (mm)

Rated Airflow (m³/h)

Initial Resistance

Filter Grade

Catalog Efficiency

JNAF-YGK

320 × 320 × 150

500

180 Pa @ 1.0 m/s

H13

≥99.99%

JNAF-YGK

484 × 484 × 150

1000

180 Pa @ 1.0 m/s

H13

≥99.99%

JNAF-YGK

630 × 630 × 150

1500

180 Pa @ 1.0 m/s

H13

≥99.99%

JNAF-YGK

945 × 484 × 150

2000

180 Pa @ 1.0 m/s

H13

≥99.99%

JNAF-YGK

320 × 320 × 220

500

180 Pa @ 1.5 m/s

H13

≥99.99%

JNAF-YGK

484 × 484 × 220

1000

180 Pa @ 1.5 m/s

H13

≥99.99%

JNAF-YGK

630 × 630 × 220

1500

180 Pa @ 1.5 m/s

H13

≥99.99%

JNAF-YGK

945 × 630 × 220

2000

180 Pa @ 1.5 m/s

H13

≥99.99%

JNAF-YGK

1260 × 630 × 220

2500

180 Pa @ 1.5 m/s

H13

≥99.99%

H14 Gel-Seal HEPA Filter Models — JN-GSHP / JN-SGSHP

The verified gel-seal series covers 400 × 400, 550 × 550, 630 × 630, 945 × 630 and 1260 × 630 mm face-size families. JN-GSHP models use 90 mm catalog depth and 180 Pa initial resistance at 0.8 m/s; JN-SGSHP models use 95 mm depth and 200 Pa at 0.8 m/s.

Both series are listed as H14 with ≥99.999% catalog efficiency. Verified materials: aluminum-profile frame, polyurethane sealant, hot-melt pleat separation, glass-fiber filter paper and baked-painted steel face mesh. Maximum catalog operating conditions: 80°C and 80% RH.

A high-efficiency filter must match the housing interface as well as the airflow requirement. The gel-seal HEPA filter uses a liquid-channel perimeter designed to engage with a compatible installation frame and create the intended sealing interface around the cassette.

The uploaded Biogreen catalog shows both side-channel and top-channel gel-seal configurations. For replacement work, confirm the existing filter dimensions and the exact channel position before production.

Series

JN-GSHP

Depth

90 mm

Series

JN-SGSHP

Depth

95 mm

Grade

H14

Efficiency

≥99.999%

Model Series

W × H × D (mm)

Rated Airflow (m³/h)

Initial Resistance

Filter Grade

Catalog Efficiency

JN-GSHP

400 × 400 × 90

500

180 Pa @ 0.8 m/s

H14

≥99.999%

JN-GSHP

550 × 550 × 90

1000

180 Pa @ 0.8 m/s

H14

≥99.999%

JN-GSHP

630 × 630 × 90

1500

180 Pa @ 0.8 m/s

H14

≥99.999%

JN-GSHP

945 × 630 × 90

2000

180 Pa @ 0.8 m/s

H14

≥99.999%

JN-GSHP

1260 × 630 × 90

2500

180 Pa @ 0.8 m/s

H14

≥99.999%

JN-SGSHP

400 × 400 × 95

500

200 Pa @ 0.8 m/s

H14

≥99.999%

JN-SGSHP

550 × 550 × 95

1000

200 Pa @ 0.8 m/s

H14

≥99.999%

JN-SGSHP

630 × 630 × 95

1500

200 Pa @ 0.8 m/s

H14

≥99.999%

JN-SGSHP

945 × 630 × 95

2000

200 Pa @ 0.8 m/s

H14

≥99.999%

JN-SGSHP

1260 × 630 × 95

2500

200 Pa @ 0.8 m/s

H14

≥99.999%

How to Select the Right HEPA Filter for Your Cleanroom System

The best HEPA air filter for an industrial cleanroom is not determined by filter grade alone. The filter must meet the required filtration level while remaining compatible with the airflow, available fan pressure, physical opening and sealing interface of the system.

01 — Confirm Filter Grade

Identify whether the project specification calls for the H13 or H14 catalog family.

02 — Match W × H × D

Measure the existing opening or filter cassette and confirm width, height and frame depth.

03 — Confirm Rated Airflow

Choose a catalog model whose rated airflow matches the terminal duty.

04 — Check Initial Resistance

Verify that the selected pressure drop is compatible with the fan / FFU / HVAC design.

05 — Confirm Seal Interface

Match EVA gasket, side gel channel or top gel channel to the existing housing configuration.

HEPA Air Filter Applications

Pharmaceutical Manufacturing

Final filtration for controlled pharmaceutical manufacturing areas, cleanroom terminal supply points and selected contamination-control applications according to the project filtration specification.

Electronics Manufacturing

High-efficiency air filtration for particle-sensitive electronics production and clean assembly areas where terminal filter size, airflow and pressure drop must match the room air system.

Semiconductor Cleanrooms

H13/H14 filter configurations for controlled environments and terminal filtration points used in semiconductor and other high-cleanliness manufacturing areas.

Medical & Laboratory Areas

HEPA filter cassettes for selected laboratory, medical-device and controlled healthcare environments according to the project risk assessment and HVAC configuration.

Food & Hygienic Processing

High-efficiency terminal filtration for controlled food-processing, packaging or hygienic production zones where the project calls for HEPA-level final filtration.

FFUs, HEPA Boxes & Laminar-Flow Equipment

Mini-pleat and gel-seal HEPA filters can be selected for compatible FFUs, high-efficiency outlets, terminal filter housings and laminar-flow equipment according to dimensions and airflow duty.

Frequently Asked Questions About HEPA Filters

HEPA means High Efficiency Particulate Air. For cleanroom purchasing, the practical specification should go beyond the term itself and include filter grade, dimensions, rated airflow, initial resistance, frame construction and sealing interface.

The uploaded catalog identifies the JN-MPHF mini-pleat series and JNAF-YGK separator series as H13 product families. Their catalog efficiency is listed as ≥99.99%, with model-specific airflow and resistance values shown in the tables on this page.

“True HEPA filter” is widely used in consumer marketing, while cleanroom procurement should rely on the specified filter grade and the applicable technical documentation. Biogreen’s catalog identifies specific H13 and H14 series rather than using “true HEPA” as the product grade.

A gel-seal HEPA filter uses a liquid-channel perimeter interface rather than relying only on a compression gasket. The existing terminal housing must be compatible with the channel position and installation interface.

Send the existing filter model or label, W × H × D dimensions, required H13/H14 grade, rated airflow, initial resistance if known, and the gasket or gel-channel position. Matching all of these inputs reduces the risk of replacement-fit errors.

There is no single replacement interval for every cleanroom. Replacement should be based on system monitoring, pressure-drop trend, maintenance procedures, integrity/performance checks and the facility’s contamination-control requirements.

No. The products on this page are industrial cleanroom and terminal-filtration components intended for FFUs, HEPA boxes, clean-air outlets and compatible housings. Residential furnace filters use different sizing, airflow and system conventions.

Custom or replacement configurations can be evaluated according to the required filter grade, W × H × D dimensions, airflow duty, resistance target and sealing interface. Provide the existing filter data when requesting a proposal.

Tell Us Your HEPA Filter Requirements

Send the filter grade, dimensions, airflow and installation interface you need. For replacement projects, a clear photo of the existing filter label and the measured W × H × D dimensions can help us identify the appropriate catalog family or custom configuration.

Recommended RFQ Inputs

Please contact us for any cleanroom needs.

Let's have a chat