CALL AN EXPERT! +86-131-3073-8426
Cleanroom pass box
A cleanroom pass box is an auxiliary equipment in a cleanroom, mainly used for the transfer of small items between clean areas and between clean and non clean areas, in order to reduce the number of cleanroom doors and minimize pollution to the cleanroom.
Cleanroom pass box principle
A cleanroom pass box is a device installed at the entrance and exit of a clean room or between rooms of different cleanliness levels, which blocks the flow of indoor and outdoor air when transferring goods, in order to prevent polluted air from entering cleaner areas and causing cross contamination. When the air shower type cleanroom pass box transfers materials, high-speed and clean airflow is blown out from the top to remove dust particles on the surface of the goods. At this time, the doors on both sides can be opened or closed, and the clean airflow acts as an airlock to ensure that the air outside the clean room does not affect the cleanliness of the room. The inner sides of the doors on both sides of the cleanroom pass box are equipped with dedicated sealing strips to ensure the air tightness of the transfer window.
cleanroom pass box classification
1. Electronic interlocking pass box
2. Mechanical interlocking pass box
3. Self purifying pass box
Advantages of pass box
The cleanroom pass box is made of stainless steel plate, which is flat and smooth. The long-distance cleanroom pass box workbench adopts a non powered drum, making it easy and convenient to transfer items. The double doors are interlocked to effectively prevent cross contamination, equipped with electronic or mechanical interlocking devices and equipped with ultraviolet sterilization lamps.
cleanroom pass box Usage program
1. A cleanroom pass box is a channel for the transfer of materials between areas of different cleanliness levels.
2. The door of the cleanroom pass box is usually closed. During material transfer, the transmitter first rings the doorbell and opens another door when the other party responds. After the material is delivered, the door is immediately closed. The receiver opens the other door, takes out the material, and then closes the door. It is strictly prohibited to open two doors at the same time.
3. After the operation is completed, the cleanroom pass box should be cleaned and regularly disinfected.
Regulations related to pass box
1. is managed according to the higher-level cleanliness level connected to it.
2. No materials or debris should be placed inside the transfer window.
3. Clean area operators are responsible for management.
use of pass box
The principle of using transfer windows is: single-sided opening. Since all transfer windows are equipped with interlocking devices, the door of the cleanroom pass box can only be opened and closed on one side. Open the door of the cleanroom pass box(if the door on the other side is not closed, it cannot be opened), put the material to be transferred into the transfer window, close the door of the transfer window, and the operator on the other side opens the door, takes out the material from the transfer window, and closes the door of the transfer window.
Health management of pass box
The cleanroom pass box should be managed according to the cleanliness level of the higher-level clean area connected to it, for example, the cleanroom pass box connected to the coding room and the filling room should be managed according to the requirements of the filling room. After the shift, the clean area operator is responsible for wiping the internal surfaces of the cleanroom pass box clean and turning on the ultraviolet sterilization lamp for 30 minutes.
matters needing attention of pass box
1. As the transmission window is equipped with an interlock, when one side of the door cannot be opened smoothly, it is due to the other side of the door not being closed properly. Do not forcefully open it, otherwise it will damage the interlock device.
2. When the material is upgraded from a lower level to a higher level of cleanliness, the surface of the material should be cleaned properly.
When the interlocking device of the transmission window cannot work properly, it should be repaired in a timely manner, otherwise it cannot be used.
4. Regularly check the working condition of the ultraviolet lamp and replace the ultraviolet lamp tube regularly.
5. No materials or debris should be stored inside the transfer window.
Usage method of pass box
(1) Materials entering and leaving the clean area must be strictly separated from the pedestrian flow channel and accessed through the dedicated material channel in the production workshop.
(2) When materials enter, the process leader of the preparation team organizes personnel to unpack or clean the surface of the raw materials, and then sends them to the temporary storage room of the workshop through the transfer window; After removing the outer packaging from the outer temporary storage room, the inner packaging materials are sent into the inner packaging room through the transfer window. The workshop coordinator and the person in charge of the preparation and internal packaging processes handle the handover of materials.
(3) When passing through the transmission window, it is necessary to strictly follow the rule of “one opening and one closing” for the inner and outer doors of the transmission window, and the two doors cannot be opened at the same time. Open the outer door to put the materials in, then close the door first, then open the inner door to take out the materials, and finally close the door, and repeat this process.
(4) When materials are sent out from the clean area, they should be transported to the relevant material intermediate station first, and then removed from the clean area according to the reverse procedure of the materials entering.
(5) All semi-finished products must be transported from the clean area to the external temporary storage room through the transfer window, and then transferred to the external packaging room through the logistics channel.
(6) Materials and waste that are highly prone to pollution should be transported from their dedicated transfer windows to non clean areas.
(7) After the completion of material entry and exit, the cleanliness of each cleaning room or intermediate station and the cleanroom pass box should be cleaned in a timely manner. The internal and external passage doors of the cleanroom pass box should be closed, and cleaning and disinfection work should be done well.