600 mm Dynamic Pass Box VCR600DP

$780.00

The VCR600DP dynamic pass box offers an approximate 600 ?? 600 ?? 600 mm chamber for trays, packaging and routine materials transferred between zones with different cleanliness requirements. A fan and HEPA filter support active air cleaning, while electronic door interlocking protects separation. Available project options include H14 filtration, pressure indication, DOP/PAO ports, UV light and control logic. Final airflow, noise, voltage and test documentation are agreed before production.
Looking to avoid the wait of build time? Contact our engineering team!

Product Summary

VCR600DP is a dynamic transfer chamber sized for routine trays, packs and tools that need active air cleaning between cleanroom zones. Compared with a 500 mm chamber, its approximate 600 ?? 600 ?? 600 mm internal space provides additional handling clearance while retaining a wall-mounted form.

ItemAvailable configuration
ChamberApprox. 600 ?? 600 ?? 600 mm
Approximate external size770 ?? 680 ?? 1100 mm; subject to approved configuration
Air cleaningFan with project-selected HEPA filter
H14 optionAvailable for higher-cleanliness projects when specified
Pressure indicationAvailable to support operating and maintenance checks
Integrity testingDOP/PAO test access can be included
Electrical supplyConfigured for destination voltage and frequency

Suitable Project Scenarios

This model can be used for filtered movement of trays, packaging, tools and components from a lower-grade side to a cleaner pharmaceutical, biotechnology, laboratory, electronics or medical-device area. The final selection depends on room classification, pressure relationship, item contamination risk and operating SOP.

Available Options

  • SUS304 inner chamber or full stainless-steel construction
  • Electronic interlock with door indicators
  • Timed fan or purge sequence
  • UV lamp for auxiliary treatment
  • Differential-pressure gauge
  • Pre-filter to protect the HEPA filter
  • HEPA integrity-test ports and agreed test records

Why Project Details Matter

Air velocity may be configured within a typical project range, but a single fixed value should not be assumed for every chamber. Filter area, fan capacity, chamber size and the required cleanroom condition all affect the final setting. Noise also varies with airflow and installation, so any limit should be stated during design review.

Maintenance and Verification

Operators should keep the chamber and seals clean and confirm that doors close fully. Maintenance teams should monitor pressure, airflow and filter condition, then replace filters according to site results and integrity testing. IQ, OQ or PQ support and the exact documentation package should be agreed before the order.

Quotation Checklist

Send room grades, item dimensions, daily transfer rate, wall details, chamber material, HEPA grade, airflow requirement, voltage, control sequence and validation documents. This allows an accurate configuration and project quotation.

Model / Size

VCR600DP; 600 ?? 600 ?? 600 mm chamber

Applications

filtered transfer of trays, packaging, tools and materials between different cleanroom grades

Please contact us for any cleanroom needs.